Dual Header Manifolds

SL150A-100D-2L-2R-580-S
Title:
Dual Header Manifolds
150/160 Series

GENTEC® 150/160 Series Manifold System is designed to supple High Purity Gas from one bank, then allow for manual switchover to the other bank after depletion of the bank. However, the switchover must be adjusted manually.

Features

• 150 Series manifold system uses R21 regulator for low flow systems

• 160 Series manifold system uses R22 regulator for high flow systems

• Dual line of cylinders avoid down time during cylinder change

• Diaphragm header valve on each side for cylinder changeover

• Piping is tested for pressure and leakage

• Optional wall mount

• Diaphragm station valves (1 per cylinder station)

• 3 foot stainless steel flex pigtail with integral check valve

 

EX:  SL150

A

50 

D

3L

3R

C580

S

14

SERIES 

 LAYOUT****

MAX. OUTLET PRESSURE

OUTLET CONNECTIONS

LEFT STATIONS

RIGHT STATIONS

INLET CONNECTIONS

PIGTAIL

OPTIONS

SL150 

A: 12” standard

50 psig

D: Diaphragm Valve

1/4" NPT(F)

11

C330: CGA330

S: 316L

1: Alarm

SL160

 

100 psig

Leave blank for no valve

22

C350: CGA350

T: Teflon

2: Flashback Arrestors

B150 

 

250 psig

 

33

C510: CGA510

 

3: Filter

B160

 

500 psig

(for SL150 only)

 44

C540: CGA540

 

R: Relief Valve

    55

C580: CGA580

 

Leave blank for no options

    

 

 

C660: CGA660

 

Can choose multiple options

      Other connections are available  

 

     

No Pigtail

00: 1/4"NPT(M)

  

 

 

• Maximum Inlet pressure: 3000 psig

• Working temperature: -40˚F-140˚F (-40˚C-60˚C)

• Pipe: 1/2” seamless stainless steel (BA grade)

• Regulator leak rate: 2 x 10-9 scc/sec Helium R21 

 

• Body: 316L Stainless Steel, Nickel-Plated Brass

• Diaphragm: 316L Stainless Steel

• Bonnet: 304, Nickel-Plated Brass

• Seat: PCTFE

• Spring: 316

 

• Research Laboratory

• Test Laboratory

• Manufacturing